Coal power in North Carolina was already on a downward trajectory in the state’s 2019 Clean Energy Plan supporting document. The report describes a fleet facing plant retirements, reduced operating levels and competition from natural gas and renewable energy. For people planning, operating or managing electricity infrastructure, those trends matter beyond the generation mix: they affect how existing units are dispatched, what modifications are considered, and how plant closures are handled.
How North Carolina’s coal fleet changed
In 2000, investor-owned utilities and independent power producers operated 13,296 megawatts (MW) of coal steam capacity in North Carolina. By 2018, reported operating capacity was 10,318 MW, a 22% decrease. The change reflected retirements of older units, alongside the addition of an 850 MW unit at Cliffside in 2012. By the end of 2018, seven coal plants remained in operation, while independent power producer facilities had stopped operating or changed fuels.
Generation fell more sharply than capacity. Coal-fired plants in the state produced 76.6 million megawatt-hours (MWh) at the 2007 peak cited in the report, compared with 31.4 million MWh in 2018. Coal’s reported share of statewide electricity generation also declined, from 62% in the early 2000s to 24% in 2018. This distinction between installed capacity and actual generation is important: a plant can remain available even when it runs fewer hours or at a lower output.
Why coal plants were running less
The report points to several pressures on coal generation: more available natural gas, lower costs in wind and solar, an aging coal fleet, and concern about environmental risks and future regulation. It also describes a change in operating patterns. Some of Duke Energy’s remaining coal capacity continued to operate as baseload generation, while other units were used at intermediate or peaking levels, with lower annual capacity factors and operating hours.
That operating flexibility has practical limits. Coal plants typically require substantial time to ramp up to full output. The document notes that newer techniques could shorten ramp times, but doing so may place additional thermal and pressure stress on plant components. As a result, dispatch decisions involve more than comparing fuel prices: operators must also consider equipment condition, operating costs and the role a unit is expected to play on the system.
Retirements, co-firing and the 2030 outlook
The 2019 document anticipated further declines in coal use, citing announced retirements of five boiler units at the Asheville and G.G. Allen plants by 2025, reducing capacity by 961 MW. It also reported that Duke Energy’s 2018 integrated resource plans did not forecast new coal steam plants in North Carolina. These are historical plans and projections from the document, not a statement of current operating status.
Another part of the outlook was modifying selected coal units to burn both coal and natural gas. The report describes planned or permitted co-firing changes at Cliffside, Belews Creek and Marshall. Burning natural gas in a coal boiler can reduce coal use, although the document estimated a heat-rate penalty of about 5% for this approach. The report projected that co-firing across the identified boilers could reduce total coal heat input by about 30% from its 2018 level. It also anticipated lower coal use alongside new natural gas combined-cycle generation.
Environmental and decommissioning considerations
Coal generation involves environmental issues that extend beyond emissions from the boiler. Combustion produces coal combustion residuals, including fly ash and bottom ash, and plant processes can produce wastewater. The report also identifies emissions of greenhouse gases, nitrogen oxides, sulfur dioxide, fine particulate matter, mercury and other pollutants. Controls and regulatory requirements shape how plants manage some of these issues.
For plant owners and communities, coal ash management is a significant consideration during operation and closure. The document describes ash disposal in surface impoundments and landfills, as well as reuse in products such as concrete or wallboard. It also recounts state enforcement actions and the 2014 Dan River coal ash spill. Decommissioning may involve utility separation, hazardous-material abatement, demolition or retirement in place, site remediation and restoration. The removal or closure of ash storage areas can add substantial complexity to the process.
What coal’s changing role means for grid planning
The report characterizes coal plants as historically reliable, fuel-secure facilities, with coal commonly stored onsite. It also notes that coal units were increasingly being used for intermediate and peaking service. At the same time, grid modernization could enable greater use of lower-cost variable renewable generation, potentially reducing the need for coal-fired output. Whether a particular unit remains useful depends on its technical capabilities, costs and place in the wider system.
For plant managers and system planners, the practical takeaway is to assess coal assets across their full lifecycle. That means considering operating patterns and maintenance needs alongside fuel flexibility, environmental compliance, ash management and eventual retirement obligations. The 2019 outlook describes a clear shift toward less coal-fired generation, but it also shows why the transition is not simply a matter of switching off capacity: decisions about dispatch, modifications and closure have operational and site-level consequences.