📘 Resource Overview & Documentation Details

You are viewing the technical directory listing for LoRaWAN Sensors for Industrial Monitoring and Metering. This engineering resource is curated under our IoT Sensors division to support automation specialists, control systems engineers, and manufacturing technicians looking for verified reference materials.

🔍 Contextual Abstract & Technical Scope

Share Summary:LinkedInEmail

LoRaWAN sensors can bring utility meters, temperature probes, tank-level instruments and discrete signals into remote monitoring systems without requiring every measurement point to have a wired network connection. For industrial teams, the practical question is not simply which wireless technology to use. It is how to connect existing equipment, collect useful data at appropriate intervals and choose devices suited to the measurement and installation environment.

A range of LoRaWAN devices addresses these needs, from dedicated sensors to interface converters and multi-input hubs. Some equipment also supports NB-IoT, giving integrators another network option for moving field data to an application.

How LoRaWAN sensors fit industrial monitoring

LoRaWAN devices can collect readings locally and transmit them to a remote application on a configured schedule. In many cases, the measurement or collection interval can be set independently from the transmission interval. This distinction allows a device to record data more frequently than it sends updates over the network.

Several devices also store readings or messages locally for later delivery. The specific capacity depends on the device: examples in this range include pulse counters with storage for 200 packets, water meters with capacity for 200 readings, and a temperature logger that stores up to 1,300 measurements. Local storage can be relevant when planning how a monitoring point handles periods without a stable network connection.

Device configuration may be performed through a USB connection and PC software, or through LoRaWAN downlink messages, depending on the device. Settings can include collection and transmission periods, thresholds, input behavior and network parameters.

Connecting meters, contacts and legacy equipment

Pulse and state inputs

A pulse counter can connect to meters or other equipment that provides pulse outputs. The described counter has four configurable digital inputs, each set for pulse counting or state detection. In pulse mode, it counts electrical pulses up to 200 Hz and supports open-collector circuits. In state mode, it can report when a dry contact opens, closes or both.

This type of interface is relevant to water, electricity and heat measurement, as well as other equipment with pulse or status outputs. A related model adds two digital outputs that can be activated by downlink messages. Those outputs require LoRaWAN Class C and external power; they are not available when operating from the battery alone.

Serial and multi-protocol connections

Where instruments expose serial interfaces, LoRaWAN converters can provide a communications path for RS-232 or RS-485 equipment. The RS-232 converter transmits serial frames transparently and can also be configured to issue a command at regular intervals and forward the response. The RS-485 version supports connections to as many as six RS-485 devices. Both are externally powered and operate as Class C devices.

A Sensor Hub is intended for installations with a mix of signal types. Its interfaces include analog and digital inputs, pulse counting, 1-Wire and RS-485 Modbus RTU. It can read and store data before sending it through LoRaWAN or NB-IoT. For NB-IoT operation, the described hub sends JSON documents using MQTT over TCP. The hub can be configured to read up to 10 Modbus registers, with supported register types including coils, discrete inputs, holding registers and input registers.

For metering systems using M-Bus, a dedicated converter can read up to 10 compatible meters. It offers transparent operation, in which a command is sent to a meter and its response returned, or query operation, in which the converter generates requests itself. Its two open-drain outputs and two inputs can also support control and status functions.

Choosing sensors for temperature and level

Temperature monitoring requirements vary by location and use case. A remote-probe sensor provides configurable high and low thresholds and can generate an alert when a limit is exceeded. Its stated measurement range is -55°C to +100°C, with accuracy varying by range. A separate temperature logger measures both its built-in temperature and an external probe, and stores up to 1,300 readings. These capabilities may suit applications such as logistics and cold-chain monitoring, where a record of changing temperatures matters as well as a current reading.

For tanks and other liquid storage, two measurement approaches are represented. An ultrasonic sensor measures the distance between the sensor and the liquid surface over a stated range greater than 12 cm and less than 400 cm. It supports three configurable high- or low-level alert thresholds. A pressure-based sensor instead uses a submerged pressure sensor to determine liquid height, with a standard range up to 6 m and other lengths available. Its stated measurement accuracy is ±1.3%.

These approaches use different measurement principles and installation arrangements. Selection should account for the tank, the required measurement range and the proposed mounting method. The ultrasonic device, for example, can use a waveguide when positioned near a tank wall.

Planning deployment and data reporting

Before specifying a device, define the signal available at each measurement point and the information the application needs. A pulse output, dry contact, 4–20 mA loop, serial interface or M-Bus connection calls for a different interface. For temperature or liquid level, consider the sensing method, probe location and required thresholds.

  • Match the input to the instrument: verify whether the source provides pulses, a contact state, an analog signal or a communications protocol.
  • Set collection and transmission periods deliberately: these can be separate settings, so establish how often readings are needed and how often the application should receive them.
  • Check power and operating mode: some devices are battery-operated, while certain functions, including Class C operation, require external power.
  • Review enclosure and mounting needs: listed devices have different ingress protection ratings and installation options, making site conditions part of device selection.
  • Confirm network and application integration: account for the chosen LoRaWAN or NB-IoT path and how readings will be delivered to the remote system.

Conclusion: choose by measurement and interface

LoRaWAN sensors and gateways are most useful when selected around the field signal, measurement objective and data-handling requirements—not as a one-size-fits-all wireless layer. Pulse counters, serial converters, multi-protocol hubs, temperature loggers and level sensors address distinct monitoring tasks. Matching the interface, power arrangement, installation conditions and reporting schedule to each point helps engineers and integrators build a more coherent remote monitoring design.

Access Official Technical PDF